Community research report · Not peer-reviewed · v1.1

Show Your Work: Can Small Open Models Read SEC Filings with Evidence a Machine Can Check?

Filing-Evidence: a pre-registered benchmark of ten open models on one consumer GPU

Status: an independent community research report, published by Pramana Research on 17 November 2026. It has not been peer-reviewed and has not been submitted to or accepted by any conference or journal. It is also available as a preprint on arXiv: arXiv:2611.24990 [cs.SE]. Version 1.1 (20 November 2026) brings this page in line with the arXiv version: a stricter rule for questions whose units are stated off-page (30 questions rather than 24), "verbatim quote" in place of "verbatim line", and a few different worked examples on the model pages; no headline figure changed. Corrections and feedback are welcome on GitHub.

In brief

We asked ten openly available AI models, small enough to run on one gaming graphics card, to find 1,000 numbers in recent SEC filings. Every answer had to come with the page and the exact line it was read from, so a computer could check it, or to say "not found" when the number wasn't there.

84.5%
answered correctly with a checkable quote by the best model (Qwen3.5-9B, check + retry)
16 in 1,000
wrong answers that still passed every automatic check, at best (Qwen3.5-9B, thinking). Most models: 64–167
57%
of those wrong-but-passing answers had the right digits in the wrong units ("thousands" vs "millions")
4 of 5
models with a thinking mode made significantly fewer wrong-but-passing answers with it
  1. Small open models can do much of this job, and the gap between them is large. In the plain setup accuracy ranges from 17.1% to 82.7%. Qwen3.5-9B is ahead of every other model by a statistically clear margin.
  2. Demanding a checkable quote works, but it isn't enough on its own. The checker stops most wrong answers. Yet the answers that pass every check include 2.4–31.8% wrong ones, depending on model and setup. Those are the dangerous errors: correct-looking evidence, wrong number.
  3. Those errors are specific and fixable. They are almost all units read wrongly or the neighbouring column (another year or quarter) of the right line, not invented numbers.
  4. Letting the model think helps more than letting it retry. Thinking cut wrong-but-passing answers for every model that has the mode, at 8–67 times the generation cost. Telling a model which check failed and letting it retry adds 0.1–3.9 points of accuracy but never reduces the dangerous errors, and for 4 models it increases them: told that its quote failed, a model often finds a line that contains its wrong number.

Abstract

Language models are increasingly used to read financial documents, but a fluent answer is not a verified one. We ask whether small open models, the kind that run on a single consumer GPU, can extract numbers from SEC filings with evidence a machine can check: the page and the verbatim line the number was read from. We built Filing-Evidence, 1,000 questions over 90 recent 10-K and 10-Q filings of 45 US companies, with gold answers taken from the filers' own inline XBRL tags, in eight kinds of content including segment tables, numbers in prose and questions whose answer is not on the pages shown. The protocol, metrics and statistics were registered before any model ran. We evaluated ten instruct models from ten companies (7–21B parameters) on one RTX 4090 in three setups: plain, check-and-retry, and the model's own thinking mode. Accuracy with checkable evidence ranges from 17.1% to 82.7% in the plain setup; the best result is 84.5% (Qwen3.5-9B). An automatic checker rejects most wrong answers, yet 16 to 167 answers per 1,000 pass every check and are still wrong; across the ten models 57% of these are scale errors and 30% the wrong column of the right line. Thinking reduces such errors significantly for 4 of 5 models; retrying after a failed check raises accuracy by up to 3.9 points but never reduces them. We release the questions, every model answer, the code and the protocol.

1 · Introduction

An analyst who copies a number from a filing can show where it came from. A language model that does the same job usually can't, or it gives a citation nobody checks. For a model to be trusted with this work its answers have to be auditable: each number should come with evidence that can be verified quickly, preferably by software.

The question is simple to state. If every answer must name the page and quote the exact line containing the number, how often are small open models right, how often are they wrong in a way the quote doesn't reveal, and do two cheap, training-free interventions help: checking the answer automatically and letting the model try again, or switching on the model's own reasoning mode? We ask it of models that fit on one 24 GB consumer GPU, because those are the models an organisation can run on its own hardware, with its own documents, at low cost.

We registered three research questions before running any model (the full protocol is in the repository):

  • RQ1. How reliably do ~10B-parameter open instruct models extract a requested number from an SEC filing with evidence that can be checked automatically, and answer "not found" when the number isn't on the pages provided?
  • RQ2. Where do they fail: in which kinds of filing content, and with which kinds of error?
  • RQ3. How much do (a) automatic checking with one retry and (b) the model's own thinking mode help, and at what cost in tokens and time?

Our working thesis was that a small open model on one consumer GPU can be a trustworthy reader of SEC filings if every answer must carry evidence a machine can check. The results support the first half of that sentence more than the second: requiring checkable evidence makes most errors visible, but a specific class of errors passes through it. Section 7 discusses what closes that gap.

2 · Benchmark design

How the benchmark is built and run Filings from SEC EDGAR; gold answers from the filers' own inline XBRL tags; 1,000 questions, reviewed and frozen; ten models served on one GPU in three setups; an automatic checker grades every answer. BUILD THE BENCHMARK (BEFORE ANY MODEL RUNS) SEC EDGAR 90 filings, 45 companieslatest 10-K and 10-Q Inline XBRL answer key the filer's own tags givevalue, unit, period, line 1,000 questions 8 kinds of content3 pages shown per question QC review, freeze 98 of 100 passedsha256 fingerprint RUN AND GRADE 10 open models, one RTX 4090 7–21B parameters, served with vLLM 3 setups plain · check + retry · thinking Automatic checker page, verbatim quote, value→ one outcome per answer
Figure 1. How the benchmark was built and run. Everything above the line was finished, reviewed and fingerprinted before any model saw a question.

2.1 Filings and answer key

We took the most recent 10-K and 10-Q filed on or before 15 November 2026 by 45 large US companies (90 filings): forty in nine sector groups chosen to cover different statement layouts (technology, banks, other financials, insurers, REITs, utilities, healthcare, consumer, industrials and others), plus five added for segment coverage. Banks, insurers, REITs and utilities are included deliberately, because their statements use line items and layouts unlike an industrial company's.

Gold answers come from the filings' own inline XBRL tags: the machine-readable layer that filers embed in the document to label each number with its concept, period, unit, scale and dimensions. We use only tags whose number is displayed on a page, and record the page and the line where it is shown. The answer key is therefore the filer's own statement, not our annotation.

2.2 Questions

Each question names an item, a company and a period in words ("What was Apple Inc.'s total liabilities as of June 27, 2026?") and comes with three pages of the filing: the page that shows the answer, an adjacent page and a random distractor, in random order. Questions fall into eight slices of 125 each:

SliceWhat it testsCompanies
S1Main statements, current period44
S2Main statements, prior period44
S310-Q quarter vs year-to-date36
S4Notes tables44
S5Segments29
S6Numbers in prose43
S7Units and per-share42
S8Not in the provided pages45

S8 asks for something that is not on the pages provided: a period not shown, an item the company doesn't report, a quarter asked of an annual report, or an item that is elsewhere in the filing but not on these pages. The correct answer is "not found". Strict rules decide which facts can become questions: the number must be a column figure on a row with a printed label, the row must be fully populated, the period's year must be visible on the page, and the question names the item by its printed row label when that label is unique on the shown pages.

2.3 Quality control and freeze

Before any model ran, 100 questions (stratified across slices) were reviewed one by one against the rendered filing by an AI assistant, under the author's direction, in each round; the protocol required at least 98 correct. Rounds one to three failed on wording (87, 76 and 96 of 100), never on gold values: all 400 gold values reviewed across the four rounds were judged right. Round four passed with 98 of 100, and the dataset was frozen with a SHA-256 fingerprint (4fa8f252292167fb…). Every result cites it, and the published data verifies against it.

2.4 The checker

Models answer in a fixed JSON format: the value, its scale ("in millions"), the page number and the line quoted from the page, or {"status": "not_found"}. The checker then applies four automatic tests (Figure 2) and compares the value with the answer key. The sign is not graded, because filers display negative numbers in inconsistent ways; values are compared after scale, and per-share amounts and percentages as displayed.

The checker: four automatic checks, then comparison with the answer key An answer that passes all four checks is either correct or confident-wrong. An answer that fails a check is rejected automatically: it is either a right value with unusable evidence or a wrong value caught by the checker. Answer value, scale,page, quote 1 Parses valid JSON fails 2 Page one of the 3 shown fails 3 Quote verbatim on page fails 4 Value appears in the quote fails passes all four Rejected automatically a system using the model would not accept this answer THEN COMPARE THE VALUE WITH THE ANSWER KEY = key ≠ key = key ≠ key Right value, unusable evidence(fixable: quote again) Caught wrong wrong, but thechecker stops it Correct right value,checkable Confident-wrong passes everycheck, wrong "not found" answers: missed, or correctly abstained (S8)
Figure 2. Four checks, then the answer key. The checker sees only the answer and the pages, never the gold, so it could run in production. Its most important outcome is the one it can't detect: confident-wrong, a wrong value whose evidence passes every check.

Every answer receives exactly one outcome. Accuracy is the share of the 875 answerable questions (S1–S7) answered correctly with evidence that passes the checks: a right number with an unusable quote does not count. Confident-wrong rate is the share of all 1,000 answers that pass every check but are wrong, and is the metric that matters most for a system that would act on answers the checker accepts. Abstention accuracy is the share of S8 questions answered "not found". Every rate carries a 95% Wilson interval; differences are tested with paired exact McNemar tests on the same questions and Holm-corrected within each family of comparisons.

3 · Models and setups

Ten general instruct models, each from a different company, all served with vLLM 0.33.0 on one NVIDIA RTX 4090 (24 GB) at temperature 0, with each model's own chat template and its exact Hugging Face revision pinned. Models are used as published: no fine-tuning, no finance-specific models, no prompt tuning per model; the prompt is identical for every model. Qwen3-8B, the model of the pilot study that motivated the benchmark, was run as a supplementary baseline and is reported separately.

ModelCompanyParamsPrecisionReleasedThinking modeLicence
Qwen3.5-9BAlibaba9.7Bbf162026-02yesApache 2.0
Granite-4.2-8BIBM8.8Bbf162026-08yesApache 2.0
Ministral-3-8BMistral8.9Bbf162025-10—Apache 2.0
OLMo-3-7BAllenAI7.3Bbf162025-11—Apache 2.0
Nemotron-Nano-9B-v2NVIDIA8.9Bbf162025-08yesNVIDIA Open Model
gpt-oss-20bOpenAI20.9Bmxfp42025-08yesApache 2.0
Phi-4Microsoft14.7Bfp82024-12—MIT
Gemma-3-12BGoogle12.2Bfp82025-03—Gemma Terms of Use
GLM-4.6V-FlashZhipu (Z.ai)10.3Bbf162025-12yesMIT
Llama-3.1-8BMeta8.0Bbf162024-07—Llama 3.1 Community
Qwen3-8B (suppl.)Alibaba8.2Bbf162025-04yesApache 2.0

Parameters as published (Qwen3.5-9B and GLM-4.6V-Flash include a vision encoder that was not loaded; gpt-oss-20b is a mixture-of-experts model with about 3.6B parameters active per token). "Released" is the month the Hugging Face repository was created. FP8 is weight quantisation by vLLM at load, used where bf16 weights would not fit; gpt-oss-20b uses its native MXFP4 weights.

The three setups Plain: one answer. Check and retry: if the answer fails a check, the model is told which check failed and answers once more. Thinking: the model reasons before answering, up to 8,192 tokens. C1 Plain Question + 3 pages → one answer up to 512 tokens C2 Check + retry C1's answer → checker fails? the model is told which check failed, answers once more C3 Thinking the model's own reasoning mode, then one answer up to 8,192 tokens every model, same prompt the message names the check, never the answer only models that have one: 6 of 11 (n/a for the rest)
Figure 3. The three setups. C2 reuses C1's first answer, so the two differ only by the retry. gpt-oss-20b has no non-reasoning mode; its C1 and C2 use the lowest reasoning effort, C3 the highest.

4 · RQ1: How reliable are they?

Accuracy against confident-wrong rate, per model and setupEach model's plain setup is joined to its check-and-retry and thinking setups. Up and to the left is better: more answers right with checkable evidence and fewer wrong answers that pass every check.0%3%6%9%12%15%18%10%20%30%40%50%60%70%80%90%Confident-wrong rate: wrong answers that pass every automatic check (of 1,000)Accuracy with checkable evidence (of 875)Qwen3.5-9BGranite-4.2-8BMinistral-3-8BOLMo-3-7BNemotron-Nano-9B-v2gpt-oss-20bPhi-4Gemma-3-12BGLM-4.6V-FlashLlama-3.1-8BQwen3.5-9B, Plain: accuracy 82.7%, confident-wrong 3.6%Qwen3.5-9B, Plain: accuracy 82.7%, confident-wrong 3.6%Qwen3.5-9B, Check + retry: accuracy 84.5%, confident-wrong 3.6%Qwen3.5-9B, Check + retry: accuracy 84.5%, confident-wrong 3.6%Qwen3.5-9B, Thinking: accuracy 74.6%, confident-wrong 1.6%Qwen3.5-9B, Thinking: accuracy 74.6%, confident-wrong 1.6%Granite-4.2-8B, Plain: accuracy 73.3%, confident-wrong 6.4%Granite-4.2-8B, Plain: accuracy 73.3%, confident-wrong 6.4%Granite-4.2-8B, Check + retry: accuracy 76.2%, confident-wrong 7.2%Granite-4.2-8B, Check + retry: accuracy 76.2%, confident-wrong 7.2%Granite-4.2-8B, Thinking: accuracy 81.3%, confident-wrong 3.8%Granite-4.2-8B, Thinking: accuracy 81.3%, confident-wrong 3.8%Ministral-3-8B, Plain: accuracy 66.7%, confident-wrong 7.7%Ministral-3-8B, Plain: accuracy 66.7%, confident-wrong 7.7%Ministral-3-8B, Check + retry: accuracy 69.6%, confident-wrong 8.6%Ministral-3-8B, Check + retry: accuracy 69.6%, confident-wrong 8.6%OLMo-3-7B, Plain: accuracy 17.1%, confident-wrong 7.0%OLMo-3-7B, Plain: accuracy 17.1%, confident-wrong 7.0%OLMo-3-7B, Check + retry: accuracy 17.3%, confident-wrong 7.0%OLMo-3-7B, Check + retry: accuracy 17.3%, confident-wrong 7.0%Nemotron-Nano-9B-v2, Plain: accuracy 42.3%, confident-wrong 10.5%Nemotron-Nano-9B-v2, Plain: accuracy 42.3%, confident-wrong 10.5%Nemotron-Nano-9B-v2, Check + retry: accuracy 42.4%, confident-wrong 10.5%Nemotron-Nano-9B-v2, Check + retry: accuracy 42.4%, confident-wrong 10.5%Nemotron-Nano-9B-v2, Thinking: accuracy 54.4%, confident-wrong 7.2%Nemotron-Nano-9B-v2, Thinking: accuracy 54.4%, confident-wrong 7.2%gpt-oss-20b, Plain: accuracy 74.4%, confident-wrong 11.2%gpt-oss-20b, Plain: accuracy 74.4%, confident-wrong 11.2%gpt-oss-20b, Check + retry: accuracy 77.4%, confident-wrong 11.8%gpt-oss-20b, Check + retry: accuracy 77.4%, confident-wrong 11.8%gpt-oss-20b, Thinking: accuracy 80.7%, confident-wrong 5.6%gpt-oss-20b, Thinking: accuracy 80.7%, confident-wrong 5.6%Phi-4, Plain: accuracy 57.3%, confident-wrong 15.1%Phi-4, Plain: accuracy 57.3%, confident-wrong 15.1%Phi-4, Check + retry: accuracy 60.8%, confident-wrong 16.7%Phi-4, Check + retry: accuracy 60.8%, confident-wrong 16.7%Gemma-3-12B, Plain: accuracy 61.4%, confident-wrong 11.7%Gemma-3-12B, Plain: accuracy 61.4%, confident-wrong 11.7%Gemma-3-12B, Check + retry: accuracy 64.3%, confident-wrong 13.4%Gemma-3-12B, Check + retry: accuracy 64.3%, confident-wrong 13.4%GLM-4.6V-Flash, Plain: accuracy 70.9%, confident-wrong 11.0%GLM-4.6V-Flash, Plain: accuracy 70.9%, confident-wrong 11.0%GLM-4.6V-Flash, Check + retry: accuracy 73.0%, confident-wrong 11.1%GLM-4.6V-Flash, Check + retry: accuracy 73.0%, confident-wrong 11.1%GLM-4.6V-Flash, Thinking: accuracy 82.3%, confident-wrong 6.1%GLM-4.6V-Flash, Thinking: accuracy 82.3%, confident-wrong 6.1%Llama-3.1-8B, Plain: accuracy 58.9%, confident-wrong 10.2%Llama-3.1-8B, Plain: accuracy 58.9%, confident-wrong 10.2%Llama-3.1-8B, Check + retry: accuracy 62.7%, confident-wrong 12.4%Llama-3.1-8B, Check + retry: accuracy 62.7%, confident-wrong 12.4%PlainCheck + retryThinkingbetter: up and to the left
Figure 4. Accuracy against confident-wrong rate for each model in each of its setups (pale: plain; mid: check + retry; dark: thinking). The ideal model sits in the top-left corner. Hover a point for its values.

Accuracy in the plain setup spans a wide range, from 17.1% for OLMo-3-7B to 82.7% (80.1–85.1%) for Qwen3.5-9B. The paired tests separate the ten models into clear tiers (Figure 6): Qwen3.5-9B is significantly more accurate than every other model; gpt-oss-20b, Granite-4.2-8B and GLM-4.6V-Flash cannot be told apart from each other; then come Ministral-3-8B, a group of Gemma-3-12B, Llama-3.1-8B and Phi-4, and finally Nemotron-Nano-9B-v2 and OLMo-3-7B. The best single result is 84.5% (Qwen3.5-9B, check + retry).

Accuracy per model and setup, with 95% Wilson intervalsAccuracy for each model in each of its setups; the line is the 95% interval.0%10%20%30%40%50%60%70%80%90%100%Qwen3.5-9BQwen3.5-9B, Plain: 82.7% (95% CI 80.1–85.1%), 724 of 875Qwen3.5-9B, Plain: 82.7% (95% CI 80.1–85.1%), 724 of 875Qwen3.5-9B, Check + retry: 84.5% (95% CI 81.9–86.7%), 739 of 875Qwen3.5-9B, Check + retry: 84.5% (95% CI 81.9–86.7%), 739 of 875Qwen3.5-9B, Thinking: 74.6% (95% CI 71.6–77.4%), 653 of 875Qwen3.5-9B, Thinking: 74.6% (95% CI 71.6–77.4%), 653 of 875gpt-oss-20bgpt-oss-20b, Plain: 74.4% (95% CI 71.4–77.2%), 651 of 875gpt-oss-20b, Plain: 74.4% (95% CI 71.4–77.2%), 651 of 875gpt-oss-20b, Check + retry: 77.4% (95% CI 74.5–80.0%), 677 of 875gpt-oss-20b, Check + retry: 77.4% (95% CI 74.5–80.0%), 677 of 875gpt-oss-20b, Thinking: 80.7% (95% CI 77.9–83.2%), 706 of 875gpt-oss-20b, Thinking: 80.7% (95% CI 77.9–83.2%), 706 of 875Granite-4.2-8BGranite-4.2-8B, Plain: 73.3% (95% CI 70.2–76.1%), 641 of 875Granite-4.2-8B, Plain: 73.3% (95% CI 70.2–76.1%), 641 of 875Granite-4.2-8B, Check + retry: 76.2% (95% CI 73.3–78.9%), 667 of 875Granite-4.2-8B, Check + retry: 76.2% (95% CI 73.3–78.9%), 667 of 875Granite-4.2-8B, Thinking: 81.3% (95% CI 78.5–83.7%), 711 of 875Granite-4.2-8B, Thinking: 81.3% (95% CI 78.5–83.7%), 711 of 875GLM-4.6V-FlashGLM-4.6V-Flash, Plain: 70.9% (95% CI 67.8–73.8%), 620 of 875GLM-4.6V-Flash, Plain: 70.9% (95% CI 67.8–73.8%), 620 of 875GLM-4.6V-Flash, Check + retry: 73.0% (95% CI 70.0–75.9%), 639 of 875GLM-4.6V-Flash, Check + retry: 73.0% (95% CI 70.0–75.9%), 639 of 875GLM-4.6V-Flash, Thinking: 82.3% (95% CI 79.6–84.7%), 720 of 875GLM-4.6V-Flash, Thinking: 82.3% (95% CI 79.6–84.7%), 720 of 875Ministral-3-8BMinistral-3-8B, Plain: 66.7% (95% CI 63.6–69.8%), 584 of 875Ministral-3-8B, Plain: 66.7% (95% CI 63.6–69.8%), 584 of 875Ministral-3-8B, Check + retry: 69.6% (95% CI 66.5–72.6%), 609 of 875Ministral-3-8B, Check + retry: 69.6% (95% CI 66.5–72.6%), 609 of 875Gemma-3-12BGemma-3-12B, Plain: 61.4% (95% CI 58.1–64.5%), 537 of 875Gemma-3-12B, Plain: 61.4% (95% CI 58.1–64.5%), 537 of 875Gemma-3-12B, Check + retry: 64.3% (95% CI 61.1–67.4%), 563 of 875Gemma-3-12B, Check + retry: 64.3% (95% CI 61.1–67.4%), 563 of 875Llama-3.1-8BLlama-3.1-8B, Plain: 58.9% (95% CI 55.6–62.1%), 515 of 875Llama-3.1-8B, Plain: 58.9% (95% CI 55.6–62.1%), 515 of 875Llama-3.1-8B, Check + retry: 62.7% (95% CI 59.5–65.9%), 549 of 875Llama-3.1-8B, Check + retry: 62.7% (95% CI 59.5–65.9%), 549 of 875Phi-4Phi-4, Plain: 57.3% (95% CI 54.0–60.5%), 501 of 875Phi-4, Plain: 57.3% (95% CI 54.0–60.5%), 501 of 875Phi-4, Check + retry: 60.8% (95% CI 57.5–64.0%), 532 of 875Phi-4, Check + retry: 60.8% (95% CI 57.5–64.0%), 532 of 875Nemotron-Nano-9B-v2Nemotron-Nano-9B-v2, Plain: 42.3% (95% CI 39.1–45.6%), 370 of 875Nemotron-Nano-9B-v2, Plain: 42.3% (95% CI 39.1–45.6%), 370 of 875Nemotron-Nano-9B-v2, Check + retry: 42.4% (95% CI 39.2–45.7%), 371 of 875Nemotron-Nano-9B-v2, Check + retry: 42.4% (95% CI 39.2–45.7%), 371 of 875Nemotron-Nano-9B-v2, Thinking: 54.4% (95% CI 51.1–57.7%), 476 of 875Nemotron-Nano-9B-v2, Thinking: 54.4% (95% CI 51.1–57.7%), 476 of 875OLMo-3-7BOLMo-3-7B, Plain: 17.1% (95% CI 14.8–19.8%), 150 of 875OLMo-3-7B, Plain: 17.1% (95% CI 14.8–19.8%), 150 of 875OLMo-3-7B, Check + retry: 17.3% (95% CI 14.9–19.9%), 151 of 875OLMo-3-7B, Check + retry: 17.3% (95% CI 14.9–19.9%), 151 of 875PlainCheck + retryThinking
Figure 5. Accuracy with 95% Wilson intervals, per model and setup, ordered by the plain setup.
Show the data
ModelC1 accuracyC1 conf.-wrongC2 accuracyC2 conf.-wrongC3 accuracyC3 conf.-wrongAbstention (C1)
Qwen3.5-9B 82.7% 80.1–85.1%36 84.5% 81.9–86.7%36 74.6% 71.6–77.4%16 124/125
gpt-oss-20b 74.4% 71.4–77.2%112 77.4% 74.5–80.0%118 80.7% 77.9–83.2%56 112/125
Granite-4.2-8B 73.3% 70.2–76.1%64 76.2% 73.3–78.9%72 81.3% 78.5–83.7%38 121/125
GLM-4.6V-Flash 70.9% 67.8–73.8%110 73.0% 70.0–75.9%111 82.3% 79.6–84.7%61 118/125
Ministral-3-8B 66.7% 63.6–69.8%77 69.6% 66.5–72.6%86 n/an/a 124/125
Gemma-3-12B 61.4% 58.1–64.5%117 64.3% 61.1–67.4%134 n/an/a 97/125
Llama-3.1-8B 58.9% 55.6–62.1%102 62.7% 59.5–65.9%124 n/an/a 110/125
Phi-4 57.3% 54.0–60.5%151 60.8% 57.5–64.0%167 n/an/a 116/125
Nemotron-Nano-9B-v2 42.3% 39.1–45.6%105 42.4% 39.2–45.7%105 54.4% 51.1–57.7%72 125/125
OLMo-3-7B 17.1% 14.8–19.8%70 17.3% 14.9–19.9%70 n/an/a 121/125
Which accuracy differences are real (Plain)Paired exact McNemar tests on the same 875 questions, Holm-corrected over all 45 pairs.Qwen3.5-9Bgpt-oss-20bGranite-4.2-8BGLM-4.6V-FlashMinistral-3-8BGemma-3-12BLlama-3.1-8BPhi-4Nemotron-Nano-9B-v2OLMo-3-7BQwen3.5-9BQwen3.5-9B vs gpt-oss-20b: right only for Qwen3.5-9B 145, only for gpt-oss-20b 72; Holm p = 9.74e-06 (significant)Qwen3.5-9B vs Granite-4.2-8B: right only for Qwen3.5-9B 142, only for Granite-4.2-8B 59; Holm p = 6.67e-08 (significant)Qwen3.5-9B vs GLM-4.6V-Flash: right only for Qwen3.5-9B 171, only for GLM-4.6V-Flash 67; Holm p = 2.08e-10 (significant)Qwen3.5-9B vs Ministral-3-8B: right only for Qwen3.5-9B 195, only for Ministral-3-8B 55; Holm p = 4.06e-18 (significant)Qwen3.5-9B vs Gemma-3-12B: right only for Qwen3.5-9B 240, only for Gemma-3-12B 53; Holm p = 4.03e-28 (significant)Qwen3.5-9B vs Llama-3.1-8B: right only for Qwen3.5-9B 249, only for Llama-3.1-8B 40; Holm p = 1.51e-36 (significant)Qwen3.5-9B vs Phi-4: right only for Qwen3.5-9B 276, only for Phi-4 53; Holm p = 5.03e-36 (significant)Qwen3.5-9B vs Nemotron-Nano-9B-v2: right only for Qwen3.5-9B 380, only for Nemotron-Nano-9B-v2 26; Holm p = 3.58e-80 (significant)Qwen3.5-9B vs OLMo-3-7B: right only for Qwen3.5-9B 588, only for OLMo-3-7B 14; Holm p = 4.49e-152 (significant)gpt-oss-20bgpt-oss-20b vs Qwen3.5-9B: right only for gpt-oss-20b 72, only for Qwen3.5-9B 145; Holm p = 9.74e-06 (significant)gpt-oss-20b vs Granite-4.2-8B: right only for gpt-oss-20b 115, only for Granite-4.2-8B 105; Holm p = 0.868 (not significant)gpt-oss-20b vs GLM-4.6V-Flash: right only for gpt-oss-20b 125, only for GLM-4.6V-Flash 94; Holm p = 0.212 (not significant)gpt-oss-20b vs Ministral-3-8B: right only for gpt-oss-20b 159, only for Ministral-3-8B 92; Holm p = 0.000308 (significant)gpt-oss-20b vs Gemma-3-12B: right only for gpt-oss-20b 197, only for Gemma-3-12B 83; Holm p = 1.42e-10 (significant)gpt-oss-20b vs Llama-3.1-8B: right only for gpt-oss-20b 217, only for Llama-3.1-8B 81; Holm p = 3.87e-14 (significant)gpt-oss-20b vs Phi-4: right only for gpt-oss-20b 220, only for Phi-4 70; Holm p = 8.4e-18 (significant)gpt-oss-20b vs Nemotron-Nano-9B-v2: right only for gpt-oss-20b 323, only for Nemotron-Nano-9B-v2 42; Holm p = 2.7e-53 (significant)gpt-oss-20b vs OLMo-3-7B: right only for gpt-oss-20b 517, only for OLMo-3-7B 16; Holm p = 5.22e-129 (significant)Granite-4.2-8BGranite-4.2-8B vs Qwen3.5-9B: right only for Granite-4.2-8B 59, only for Qwen3.5-9B 142; Holm p = 6.67e-08 (significant)Granite-4.2-8B vs gpt-oss-20b: right only for Granite-4.2-8B 105, only for gpt-oss-20b 115; Holm p = 0.868 (not significant)Granite-4.2-8B vs GLM-4.6V-Flash: right only for Granite-4.2-8B 120, only for GLM-4.6V-Flash 99; Holm p = 0.706 (not significant)Granite-4.2-8B vs Ministral-3-8B: right only for Granite-4.2-8B 141, only for Ministral-3-8B 84; Holm p = 0.00158 (significant)Granite-4.2-8B vs Gemma-3-12B: right only for Granite-4.2-8B 184, only for Gemma-3-12B 80; Holm p = 2.28e-09 (significant)Granite-4.2-8B vs Llama-3.1-8B: right only for Granite-4.2-8B 205, only for Llama-3.1-8B 79; Holm p = 9.56e-13 (significant)Granite-4.2-8B vs Phi-4: right only for Granite-4.2-8B 212, only for Phi-4 72; Holm p = 8.56e-16 (significant)Granite-4.2-8B vs Nemotron-Nano-9B-v2: right only for Granite-4.2-8B 306, only for Nemotron-Nano-9B-v2 35; Holm p = 1.28e-53 (significant)Granite-4.2-8B vs OLMo-3-7B: right only for Granite-4.2-8B 505, only for OLMo-3-7B 14; Holm p = 5.1e-128 (significant)GLM-4.6V-FlashGLM-4.6V-Flash vs Qwen3.5-9B: right only for GLM-4.6V-Flash 67, only for Qwen3.5-9B 171; Holm p = 2.08e-10 (significant)GLM-4.6V-Flash vs gpt-oss-20b: right only for GLM-4.6V-Flash 94, only for gpt-oss-20b 125; Holm p = 0.212 (not significant)GLM-4.6V-Flash vs Granite-4.2-8B: right only for GLM-4.6V-Flash 99, only for Granite-4.2-8B 120; Holm p = 0.706 (not significant)GLM-4.6V-Flash vs Ministral-3-8B: right only for GLM-4.6V-Flash 134, only for Ministral-3-8B 98; Holm p = 0.15 (not significant)GLM-4.6V-Flash vs Gemma-3-12B: right only for GLM-4.6V-Flash 162, only for Gemma-3-12B 79; Holm p = 1.35e-06 (significant)GLM-4.6V-Flash vs Llama-3.1-8B: right only for GLM-4.6V-Flash 188, only for Llama-3.1-8B 83; Holm p = 2.53e-09 (significant)GLM-4.6V-Flash vs Phi-4: right only for GLM-4.6V-Flash 206, only for Phi-4 87; Holm p = 5.47e-11 (significant)GLM-4.6V-Flash vs Nemotron-Nano-9B-v2: right only for GLM-4.6V-Flash 299, only for Nemotron-Nano-9B-v2 49; Holm p = 2.31e-43 (significant)GLM-4.6V-Flash vs OLMo-3-7B: right only for GLM-4.6V-Flash 487, only for OLMo-3-7B 17; Holm p = 3.11e-119 (significant)Ministral-3-8BMinistral-3-8B vs Qwen3.5-9B: right only for Ministral-3-8B 55, only for Qwen3.5-9B 195; Holm p = 4.06e-18 (significant)Ministral-3-8B vs gpt-oss-20b: right only for Ministral-3-8B 92, only for gpt-oss-20b 159; Holm p = 0.000308 (significant)Ministral-3-8B vs Granite-4.2-8B: right only for Ministral-3-8B 84, only for Granite-4.2-8B 141; Holm p = 0.00158 (significant)Ministral-3-8B vs GLM-4.6V-Flash: right only for Ministral-3-8B 98, only for GLM-4.6V-Flash 134; Holm p = 0.15 (not significant)Ministral-3-8B vs Gemma-3-12B: right only for Ministral-3-8B 144, only for Gemma-3-12B 97; Holm p = 0.0237 (significant)Ministral-3-8B vs Llama-3.1-8B: right only for Ministral-3-8B 171, only for Llama-3.1-8B 102; Holm p = 0.000353 (significant)Ministral-3-8B vs Phi-4: right only for Ministral-3-8B 176, only for Phi-4 93; Holm p = 6.11e-06 (significant)Ministral-3-8B vs Nemotron-Nano-9B-v2: right only for Ministral-3-8B 257, only for Nemotron-Nano-9B-v2 43; Holm p = 8.92e-37 (significant)Ministral-3-8B vs OLMo-3-7B: right only for Ministral-3-8B 456, only for OLMo-3-7B 22; Holm p = 5.33e-105 (significant)Gemma-3-12BGemma-3-12B vs Qwen3.5-9B: right only for Gemma-3-12B 53, only for Qwen3.5-9B 240; Holm p = 4.03e-28 (significant)Gemma-3-12B vs gpt-oss-20b: right only for Gemma-3-12B 83, only for gpt-oss-20b 197; Holm p = 1.42e-10 (significant)Gemma-3-12B vs Granite-4.2-8B: right only for Gemma-3-12B 80, only for Granite-4.2-8B 184; Holm p = 2.28e-09 (significant)Gemma-3-12B vs GLM-4.6V-Flash: right only for Gemma-3-12B 79, only for GLM-4.6V-Flash 162; Holm p = 1.35e-06 (significant)Gemma-3-12B vs Ministral-3-8B: right only for Gemma-3-12B 97, only for Ministral-3-8B 144; Holm p = 0.0237 (significant)Gemma-3-12B vs Llama-3.1-8B: right only for Gemma-3-12B 140, only for Llama-3.1-8B 118; Holm p = 0.706 (not significant)Gemma-3-12B vs Phi-4: right only for Gemma-3-12B 149, only for Phi-4 113; Holm p = 0.182 (not significant)Gemma-3-12B vs Nemotron-Nano-9B-v2: right only for Gemma-3-12B 229, only for Nemotron-Nano-9B-v2 62; Holm p = 3.18e-22 (significant)Gemma-3-12B vs OLMo-3-7B: right only for Gemma-3-12B 415, only for OLMo-3-7B 28; Holm p = 6.51e-88 (significant)Llama-3.1-8BLlama-3.1-8B vs Qwen3.5-9B: right only for Llama-3.1-8B 40, only for Qwen3.5-9B 249; Holm p = 1.51e-36 (significant)Llama-3.1-8B vs gpt-oss-20b: right only for Llama-3.1-8B 81, only for gpt-oss-20b 217; Holm p = 3.87e-14 (significant)Llama-3.1-8B vs Granite-4.2-8B: right only for Llama-3.1-8B 79, only for Granite-4.2-8B 205; Holm p = 9.56e-13 (significant)Llama-3.1-8B vs GLM-4.6V-Flash: right only for Llama-3.1-8B 83, only for GLM-4.6V-Flash 188; Holm p = 2.53e-09 (significant)Llama-3.1-8B vs Ministral-3-8B: right only for Llama-3.1-8B 102, only for Ministral-3-8B 171; Holm p = 0.000353 (significant)Llama-3.1-8B vs Gemma-3-12B: right only for Llama-3.1-8B 118, only for Gemma-3-12B 140; Holm p = 0.706 (not significant)Llama-3.1-8B vs Phi-4: right only for Llama-3.1-8B 145, only for Phi-4 131; Holm p = 0.868 (not significant)Llama-3.1-8B vs Nemotron-Nano-9B-v2: right only for Llama-3.1-8B 223, only for Nemotron-Nano-9B-v2 78; Holm p = 6.1e-16 (significant)Llama-3.1-8B vs OLMo-3-7B: right only for Llama-3.1-8B 396, only for OLMo-3-7B 31; Holm p = 3.4e-80 (significant)Phi-4Phi-4 vs Qwen3.5-9B: right only for Phi-4 53, only for Qwen3.5-9B 276; Holm p = 5.03e-36 (significant)Phi-4 vs gpt-oss-20b: right only for Phi-4 70, only for gpt-oss-20b 220; Holm p = 8.4e-18 (significant)Phi-4 vs Granite-4.2-8B: right only for Phi-4 72, only for Granite-4.2-8B 212; Holm p = 8.56e-16 (significant)Phi-4 vs GLM-4.6V-Flash: right only for Phi-4 87, only for GLM-4.6V-Flash 206; Holm p = 5.47e-11 (significant)Phi-4 vs Ministral-3-8B: right only for Phi-4 93, only for Ministral-3-8B 176; Holm p = 6.11e-06 (significant)Phi-4 vs Gemma-3-12B: right only for Phi-4 113, only for Gemma-3-12B 149; Holm p = 0.182 (not significant)Phi-4 vs Llama-3.1-8B: right only for Phi-4 131, only for Llama-3.1-8B 145; Holm p = 0.868 (not significant)Phi-4 vs Nemotron-Nano-9B-v2: right only for Phi-4 217, only for Nemotron-Nano-9B-v2 86; Holm p = 7.09e-13 (significant)Phi-4 vs OLMo-3-7B: right only for Phi-4 385, only for OLMo-3-7B 34; Holm p = 7.33e-75 (significant)Nemotron-Nano-9B-v2Nemotron-Nano-9B-v2 vs Qwen3.5-9B: right only for Nemotron-Nano-9B-v2 26, only for Qwen3.5-9B 380; Holm p = 3.58e-80 (significant)Nemotron-Nano-9B-v2 vs gpt-oss-20b: right only for Nemotron-Nano-9B-v2 42, only for gpt-oss-20b 323; Holm p = 2.7e-53 (significant)Nemotron-Nano-9B-v2 vs Granite-4.2-8B: right only for Nemotron-Nano-9B-v2 35, only for Granite-4.2-8B 306; Holm p = 1.28e-53 (significant)Nemotron-Nano-9B-v2 vs GLM-4.6V-Flash: right only for Nemotron-Nano-9B-v2 49, only for GLM-4.6V-Flash 299; Holm p = 2.31e-43 (significant)Nemotron-Nano-9B-v2 vs Ministral-3-8B: right only for Nemotron-Nano-9B-v2 43, only for Ministral-3-8B 257; Holm p = 8.92e-37 (significant)Nemotron-Nano-9B-v2 vs Gemma-3-12B: right only for Nemotron-Nano-9B-v2 62, only for Gemma-3-12B 229; Holm p = 3.18e-22 (significant)Nemotron-Nano-9B-v2 vs Llama-3.1-8B: right only for Nemotron-Nano-9B-v2 78, only for Llama-3.1-8B 223; Holm p = 6.1e-16 (significant)Nemotron-Nano-9B-v2 vs Phi-4: right only for Nemotron-Nano-9B-v2 86, only for Phi-4 217; Holm p = 7.09e-13 (significant)Nemotron-Nano-9B-v2 vs OLMo-3-7B: right only for Nemotron-Nano-9B-v2 276, only for OLMo-3-7B 56; Holm p = 1.34e-34 (significant)OLMo-3-7BOLMo-3-7B vs Qwen3.5-9B: right only for OLMo-3-7B 14, only for Qwen3.5-9B 588; Holm p = 4.49e-152 (significant)OLMo-3-7B vs gpt-oss-20b: right only for OLMo-3-7B 16, only for gpt-oss-20b 517; Holm p = 5.22e-129 (significant)OLMo-3-7B vs Granite-4.2-8B: right only for OLMo-3-7B 14, only for Granite-4.2-8B 505; Holm p = 5.1e-128 (significant)OLMo-3-7B vs GLM-4.6V-Flash: right only for OLMo-3-7B 17, only for GLM-4.6V-Flash 487; Holm p = 3.11e-119 (significant)OLMo-3-7B vs Ministral-3-8B: right only for OLMo-3-7B 22, only for Ministral-3-8B 456; Holm p = 5.33e-105 (significant)OLMo-3-7B vs Gemma-3-12B: right only for OLMo-3-7B 28, only for Gemma-3-12B 415; Holm p = 6.51e-88 (significant)OLMo-3-7B vs Llama-3.1-8B: right only for OLMo-3-7B 31, only for Llama-3.1-8B 396; Holm p = 3.4e-80 (significant)OLMo-3-7B vs Phi-4: right only for OLMo-3-7B 34, only for Phi-4 385; Holm p = 7.33e-75 (significant)OLMo-3-7B vs Nemotron-Nano-9B-v2: right only for OLMo-3-7B 56, only for Nemotron-Nano-9B-v2 276; Holm p = 1.34e-34 (significant)Row betterRow worseNo significant difference
Figure 6. Which differences in plain-setup accuracy are real. Each cell compares the row model with the column model on the same 875 questions (paired exact McNemar, Holm-corrected over 45 pairs). Grey cells: the data cannot separate the two.

The checker is the reason these accuracy figures mean something. An answer only counts when its quote is on the cited page and contains the number. Without that requirement the figures would be higher for every model: a right number with an unusable quote is common for weaker models (Figure 7). For a reader of the output that difference is the whole point: a right number you can't verify is not much more useful than a wrong one.

Where the answers go (875 answerable questions)Each bar splits the answerable questions by outcome, from correct (left) through missed to wrong answers caught by the checker and wrong answers that passed every check (right).0%25%50%75%100%Qwen3.5-9BQwen3.5-9B: Correct 724 of 875 (82.7%)83%Qwen3.5-9B: Right value, unusable evidence 46 of 875 (5.3%)Qwen3.5-9B: Missed (said not found) 65 of 875 (7.4%)Qwen3.5-9B: Wrong, caught by the checker 4 of 875 (0.5%)Qwen3.5-9B: Wrong, passed every check 36 of 875 (4.1%)gpt-oss-20bgpt-oss-20b: Correct 651 of 875 (74.4%)74%gpt-oss-20b: Right value, unusable evidence 62 of 875 (7.1%)gpt-oss-20b: Missed (said not found) 14 of 875 (1.6%)gpt-oss-20b: Unparseable 3 of 875 (0.3%)gpt-oss-20b: Wrong, caught by the checker 33 of 875 (3.8%)gpt-oss-20b: Wrong, passed every check 112 of 875 (12.8%)13%Granite-4.2-8BGranite-4.2-8B: Correct 641 of 875 (73.3%)73%Granite-4.2-8B: Right value, unusable evidence 48 of 875 (5.5%)Granite-4.2-8B: Missed (said not found) 48 of 875 (5.5%)Granite-4.2-8B: Unparseable 5 of 875 (0.6%)Granite-4.2-8B: Wrong, caught by the checker 69 of 875 (7.9%)Granite-4.2-8B: Wrong, passed every check 64 of 875 (7.3%)7%GLM-4.6V-FlashGLM-4.6V-Flash: Correct 620 of 875 (70.9%)71%GLM-4.6V-Flash: Right value, unusable evidence 45 of 875 (5.1%)GLM-4.6V-Flash: Missed (said not found) 21 of 875 (2.4%)GLM-4.6V-Flash: Unparseable 71 of 875 (8.1%)GLM-4.6V-Flash: Wrong, caught by the checker 8 of 875 (0.9%)GLM-4.6V-Flash: Wrong, passed every check 110 of 875 (12.6%)13%Ministral-3-8BMinistral-3-8B: Correct 584 of 875 (66.7%)67%Ministral-3-8B: Right value, unusable evidence 104 of 875 (11.9%)Ministral-3-8B: Missed (said not found) 79 of 875 (9.0%)Ministral-3-8B: Wrong, caught by the checker 31 of 875 (3.5%)Ministral-3-8B: Wrong, passed every check 77 of 875 (8.8%)9%Gemma-3-12BGemma-3-12B: Correct 537 of 875 (61.4%)61%Gemma-3-12B: Right value, unusable evidence 121 of 875 (13.8%)Gemma-3-12B: Missed (said not found) 11 of 875 (1.3%)Gemma-3-12B: Unparseable 1 of 875 (0.1%)Gemma-3-12B: Wrong, caught by the checker 88 of 875 (10.1%)Gemma-3-12B: Wrong, passed every check 117 of 875 (13.4%)13%Llama-3.1-8BLlama-3.1-8B: Correct 515 of 875 (58.9%)59%Llama-3.1-8B: Right value, unusable evidence 128 of 875 (14.6%)Llama-3.1-8B: Missed (said not found) 27 of 875 (3.1%)Llama-3.1-8B: Unparseable 3 of 875 (0.3%)Llama-3.1-8B: Wrong, caught by the checker 101 of 875 (11.5%)Llama-3.1-8B: Wrong, passed every check 102 of 875 (11.7%)12%Phi-4Phi-4: Correct 501 of 875 (57.3%)57%Phi-4: Right value, unusable evidence 107 of 875 (12.2%)Phi-4: Missed (said not found) 46 of 875 (5.3%)Phi-4: Unparseable 1 of 875 (0.1%)Phi-4: Wrong, caught by the checker 69 of 875 (7.9%)Phi-4: Wrong, passed every check 151 of 875 (17.3%)17%Nemotron-Nano-9B-v2Nemotron-Nano-9B-v2: Correct 370 of 875 (42.3%)42%Nemotron-Nano-9B-v2: Right value, unusable evidence 159 of 875 (18.2%)Nemotron-Nano-9B-v2: Missed (said not found) 174 of 875 (19.9%)Nemotron-Nano-9B-v2: Wrong, caught by the checker 67 of 875 (7.7%)Nemotron-Nano-9B-v2: Wrong, passed every check 105 of 875 (12.0%)12%OLMo-3-7BOLMo-3-7B: Correct 150 of 875 (17.1%)17%OLMo-3-7B: Right value, unusable evidence 231 of 875 (26.4%)OLMo-3-7B: Missed (said not found) 120 of 875 (13.7%)OLMo-3-7B: Unparseable 5 of 875 (0.6%)OLMo-3-7B: Wrong, caught by the checker 299 of 875 (34.2%)OLMo-3-7B: Wrong, passed every check 70 of 875 (8.0%)8%CorrectRight, bad evidenceMissedUnparseableWrong, caughtWrong, passed checks
Figure 7. What happens to the 875 answerable questions in the plain setup. Left of the grey band, the model was right; right of it, wrong. The dark red segment is the one that matters most: wrong answers that pass every check.

"Not found" is handled well by most models. Abstention accuracy in the plain setup ranges from 77.6% to 100.0%: models rarely invent a number for something that isn't on the page. Most invented answers come from one kind of trap: a quarterly figure asked of an annual report, which the filing can't contain. Gemma-3-12B, the weakest abstainer among the ten (77.6%), answered 17 of those 31 correctly, and the supplementary Qwen3-8B only 6.

5 · RQ2: Where do they fail?

5.1 By kind of content

Accuracy by kind of content (Plain)Rows are models, columns are the eight slices; darker is more accurate. S8 is the share of correct 'not found' answers.S1CurrentS2PriorS3Qtr/YTDS4NotesS5SegmentsS6ProseS7UnitsS8AbsentQwen3.5-9BQwen3.5-9B, S1 Main statements, current period: 94.4% (118 of 125)94Qwen3.5-9B, S2 Main statements, prior period: 92.8% (116 of 125)93Qwen3.5-9B, S3 10-Q quarter vs year-to-date: 96.0% (120 of 125)96Qwen3.5-9B, S4 Notes tables: 88.0% (110 of 125)88Qwen3.5-9B, S5 Segments: 71.2% (89 of 125)71Qwen3.5-9B, S6 Numbers in prose: 57.6% (72 of 125)58Qwen3.5-9B, S7 Units and per-share: 79.2% (99 of 125)79Qwen3.5-9B, S8 Not in the provided pages: 99.2% (124 of 125)99gpt-oss-20bgpt-oss-20b, S1 Main statements, current period: 96.8% (121 of 125)97gpt-oss-20b, S2 Main statements, prior period: 83.2% (104 of 125)83gpt-oss-20b, S3 10-Q quarter vs year-to-date: 70.4% (88 of 125)70gpt-oss-20b, S4 Notes tables: 80.8% (101 of 125)81gpt-oss-20b, S5 Segments: 52.8% (66 of 125)53gpt-oss-20b, S6 Numbers in prose: 72.8% (91 of 125)73gpt-oss-20b, S7 Units and per-share: 64.0% (80 of 125)64gpt-oss-20b, S8 Not in the provided pages: 89.6% (112 of 125)90Granite-4.2-8BGranite-4.2-8B, S1 Main statements, current period: 96.0% (120 of 125)96Granite-4.2-8B, S2 Main statements, prior period: 83.2% (104 of 125)83Granite-4.2-8B, S3 10-Q quarter vs year-to-date: 83.2% (104 of 125)83Granite-4.2-8B, S4 Notes tables: 86.4% (108 of 125)86Granite-4.2-8B, S5 Segments: 55.2% (69 of 125)55Granite-4.2-8B, S6 Numbers in prose: 41.6% (52 of 125)42Granite-4.2-8B, S7 Units and per-share: 67.2% (84 of 125)67Granite-4.2-8B, S8 Not in the provided pages: 96.8% (121 of 125)97GLM-4.6V-FlashGLM-4.6V-Flash, S1 Main statements, current period: 92.0% (115 of 125)92GLM-4.6V-Flash, S2 Main statements, prior period: 72.0% (90 of 125)72GLM-4.6V-Flash, S3 10-Q quarter vs year-to-date: 86.4% (108 of 125)86GLM-4.6V-Flash, S4 Notes tables: 82.4% (103 of 125)82GLM-4.6V-Flash, S5 Segments: 68.0% (85 of 125)68GLM-4.6V-Flash, S6 Numbers in prose: 37.6% (47 of 125)38GLM-4.6V-Flash, S7 Units and per-share: 57.6% (72 of 125)58GLM-4.6V-Flash, S8 Not in the provided pages: 94.4% (118 of 125)94Ministral-3-8BMinistral-3-8B, S1 Main statements, current period: 92.8% (116 of 125)93Ministral-3-8B, S2 Main statements, prior period: 64.8% (81 of 125)65Ministral-3-8B, S3 10-Q quarter vs year-to-date: 77.6% (97 of 125)78Ministral-3-8B, S4 Notes tables: 76.0% (95 of 125)76Ministral-3-8B, S5 Segments: 62.4% (78 of 125)62Ministral-3-8B, S6 Numbers in prose: 40.8% (51 of 125)41Ministral-3-8B, S7 Units and per-share: 52.8% (66 of 125)53Ministral-3-8B, S8 Not in the provided pages: 99.2% (124 of 125)99Gemma-3-12BGemma-3-12B, S1 Main statements, current period: 81.6% (102 of 125)82Gemma-3-12B, S2 Main statements, prior period: 80.0% (100 of 125)80Gemma-3-12B, S3 10-Q quarter vs year-to-date: 72.8% (91 of 125)73Gemma-3-12B, S4 Notes tables: 60.8% (76 of 125)61Gemma-3-12B, S5 Segments: 49.6% (62 of 125)50Gemma-3-12B, S6 Numbers in prose: 40.8% (51 of 125)41Gemma-3-12B, S7 Units and per-share: 44.0% (55 of 125)44Gemma-3-12B, S8 Not in the provided pages: 77.6% (97 of 125)78Llama-3.1-8BLlama-3.1-8B, S1 Main statements, current period: 69.6% (87 of 125)70Llama-3.1-8B, S2 Main statements, prior period: 71.2% (89 of 125)71Llama-3.1-8B, S3 10-Q quarter vs year-to-date: 85.6% (107 of 125)86Llama-3.1-8B, S4 Notes tables: 64.8% (81 of 125)65Llama-3.1-8B, S5 Segments: 32.8% (41 of 125)33Llama-3.1-8B, S6 Numbers in prose: 40.8% (51 of 125)41Llama-3.1-8B, S7 Units and per-share: 47.2% (59 of 125)47Llama-3.1-8B, S8 Not in the provided pages: 88.0% (110 of 125)88Phi-4Phi-4, S1 Main statements, current period: 72.0% (90 of 125)72Phi-4, S2 Main statements, prior period: 67.2% (84 of 125)67Phi-4, S3 10-Q quarter vs year-to-date: 70.4% (88 of 125)70Phi-4, S4 Notes tables: 64.0% (80 of 125)64Phi-4, S5 Segments: 29.6% (37 of 125)30Phi-4, S6 Numbers in prose: 47.2% (59 of 125)47Phi-4, S7 Units and per-share: 50.4% (63 of 125)50Phi-4, S8 Not in the provided pages: 92.8% (116 of 125)93Nemotron-Nano-9B-v2Nemotron-Nano-9B-v2, S1 Main statements, current period: 62.4% (78 of 125)62Nemotron-Nano-9B-v2, S2 Main statements, prior period: 47.2% (59 of 125)47Nemotron-Nano-9B-v2, S3 10-Q quarter vs year-to-date: 56.0% (70 of 125)56Nemotron-Nano-9B-v2, S4 Notes tables: 49.6% (62 of 125)50Nemotron-Nano-9B-v2, S5 Segments: 28.0% (35 of 125)28Nemotron-Nano-9B-v2, S6 Numbers in prose: 26.4% (33 of 125)26Nemotron-Nano-9B-v2, S7 Units and per-share: 26.4% (33 of 125)26Nemotron-Nano-9B-v2, S8 Not in the provided pages: 100.0% (125 of 125)100OLMo-3-7BOLMo-3-7B, S1 Main statements, current period: 34.4% (43 of 125)34OLMo-3-7B, S2 Main statements, prior period: 9.6% (12 of 125)10OLMo-3-7B, S3 10-Q quarter vs year-to-date: 20.8% (26 of 125)21OLMo-3-7B, S4 Notes tables: 20.8% (26 of 125)21OLMo-3-7B, S5 Segments: 10.4% (13 of 125)10OLMo-3-7B, S6 Numbers in prose: 8.0% (10 of 125)8OLMo-3-7B, S7 Units and per-share: 16.0% (20 of 125)16OLMo-3-7B, S8 Not in the provided pages: 96.8% (121 of 125)97
Figure 8. Plain-setup accuracy by slice (S8: correct "not found"). Darker is better.

The main statements are the easiest content: pooled over the ten models, 79.2% of current-period questions are answered correctly. Accuracy falls on prior-period columns (67.1%), in notes (67.4%), and most of all for segments (46.0%), numbers in prose (41.4%) and units and per-share figures (50.5%). Even Qwen3.5-9B, strong everywhere else, answers only 57.6% of prose questions correctly. These are the places where a filing's layout stops doing the work: a segment table's columns are business lines rather than years, and a number in a sentence has no column header at all.

5.2 What the dangerous errors are

What the wrong-but-passing answers got wrongFor each model, its confident-wrong answers split by error type.0255075100125150175Qwen3.5-9BQwen3.5-9B: Scale or unit 2Qwen3.5-9B: Wrong period or column 25Qwen3.5-9B: Wrong item 936Granite-4.2-8BGranite-4.2-8B: Scale or unit 16Granite-4.2-8B: Wrong period or column 35Granite-4.2-8B: Wrong item 1364OLMo-3-7BOLMo-3-7B: Scale or unit 37OLMo-3-7B: Wrong period or column 29OLMo-3-7B: Wrong item 470Ministral-3-8BMinistral-3-8B: Scale or unit 53Ministral-3-8B: Wrong period or column 16Ministral-3-8B: Wrong item 877Llama-3.1-8BLlama-3.1-8B: Scale or unit 62Llama-3.1-8B: Wrong period or column 23Llama-3.1-8B: Wrong item 17102Nemotron-Nano-9B-v2Nemotron-Nano-9B-v2: Scale or unit 66Nemotron-Nano-9B-v2: Wrong period or column 28Nemotron-Nano-9B-v2: Wrong item 11105GLM-4.6V-FlashGLM-4.6V-Flash: Scale or unit 67GLM-4.6V-Flash: Wrong period or column 35GLM-4.6V-Flash: Wrong item 8110gpt-oss-20bgpt-oss-20b: Scale or unit 57gpt-oss-20b: Wrong period or column 45gpt-oss-20b: Wrong item 10112Gemma-3-12BGemma-3-12B: Scale or unit 64Gemma-3-12B: Wrong period or column 29Gemma-3-12B: Wrong item 24117Phi-4Phi-4: Scale or unit 116Phi-4: Wrong period or column 17Phi-4: Wrong item 18151Scale or unitWrong period or columnWrong item
Figure 9. The confident-wrong answers of each model in the plain setup, by kind of error. Scale or unit: the right digits with the wrong multiplier. Wrong period or column: another figure from the right line. Wrong item: a different line.

Across the ten models there are 944 confident-wrong answers in the plain setup. Only 13% are a wrong item. The rest are near misses on the right line:

  • Scale or unit (57%). The model quotes the correct line and gives the correct digits, but states the wrong scale, most often "none" for a table headed "(In millions)", or reads a share count as shares rather than millions of shares. The checker can't catch this, because the quote is genuine and contains the number; the units are stated once, at the top of the table.
  • Wrong period or column (30%). The model quotes the right line and takes the figure for another year, quarter or year-to-date column. The quote again contains the number, so it passes.

Scale errors are concentrated in a few models: they are 116 of Phi-4's 151 confident-wrong answers, but 2 of Qwen3.5-9B's 36. The secondary metric accuracy ignoring scale shows how much of each gap is units rather than finding the number: for Phi-4 it is 70.5% against an accuracy of 57.3%.

Bank of America Corporation · 10-Q · slice S2 · page 48 (excerpt)

“What was Bank of America Corporation's net change in derivatives for the nine months ended September 30, 2025?”

The line on page 48, as the model saw it:

Net change in derivatives (1,496) 636 (2,874) 3,145

Model's answer
-2874 in millions, page 48
Its quote
Net change in derivatives (1,496) 636 (2,874) 3,145
Checks
parses ✓ · page shown ✓ · quote verbatim ✓ · value in quote ✓
Answer key
3,145
Outcome
Confident-wrong the right line, another column (model vs answer key)
Figure 10. A real confident-wrong answer from the strongest model in the plain setup. Every check passes, because the quoted line is genuine and contains the number; only the column is wrong. Of the ten models on this question, 0 answered correctly.

6 · RQ3: Retry or think?

What check + retry and thinking change, compared with the plain setupLeft: change in accuracy. Right: change in the number of confident-wrong answers. Filled dots are significant after Holm correction; hollow dots are not.Accuracy change (points)-15-10-50+5+10+15Qwen3.5-9BQwen3.5-9B, Check + retry vs plain: +1.7 (significant, Holm p = 0.000427)Qwen3.5-9B, Check + retry vs plain: +1.7 (significant, Holm p = 0.000427)Qwen3.5-9B, Thinking vs plain: -8.1 (significant, Holm p = 7.35e-05)Qwen3.5-9B, Thinking vs plain: -8.1 (significant, Holm p = 7.35e-05)gpt-oss-20bgpt-oss-20b, Check + retry vs plain: +3.0 (significant, Holm p = 4.77e-07)gpt-oss-20b, Check + retry vs plain: +3.0 (significant, Holm p = 4.77e-07)gpt-oss-20b, Thinking vs plain: +6.3 (significant, Holm p = 0.000462)gpt-oss-20b, Thinking vs plain: +6.3 (significant, Holm p = 0.000462)Granite-4.2-8BGranite-4.2-8B, Check + retry vs plain: +3.0 (significant, Holm p = 4.77e-07)Granite-4.2-8B, Check + retry vs plain: +3.0 (significant, Holm p = 4.77e-07)Granite-4.2-8B, Thinking vs plain: +8.0 (significant, Holm p = 0.00011)Granite-4.2-8B, Thinking vs plain: +8.0 (significant, Holm p = 0.00011)GLM-4.6V-FlashGLM-4.6V-Flash, Check + retry vs plain: +2.2 (significant, Holm p = 4.2e-05)GLM-4.6V-Flash, Check + retry vs plain: +2.2 (significant, Holm p = 4.2e-05)GLM-4.6V-Flash, Thinking vs plain: +11.4 (significant, Holm p = 1.45e-11)GLM-4.6V-Flash, Thinking vs plain: +11.4 (significant, Holm p = 1.45e-11)Ministral-3-8BMinistral-3-8B, Check + retry vs plain: +2.9 (significant, Holm p = 7.75e-07)Ministral-3-8B, Check + retry vs plain: +2.9 (significant, Holm p = 7.75e-07)Gemma-3-12BGemma-3-12B, Check + retry vs plain: +3.0 (significant, Holm p = 4.77e-07)Gemma-3-12B, Check + retry vs plain: +3.0 (significant, Holm p = 4.77e-07)Llama-3.1-8BLlama-3.1-8B, Check + retry vs plain: +3.9 (significant, Holm p = 2.56e-09)Llama-3.1-8B, Check + retry vs plain: +3.9 (significant, Holm p = 2.56e-09)Phi-4Phi-4, Check + retry vs plain: +3.5 (significant, Holm p = 1.96e-08)Phi-4, Check + retry vs plain: +3.5 (significant, Holm p = 1.96e-08)Nemotron-Nano-9B-v2Nemotron-Nano-9B-v2, Check + retry vs plain: +0.1 (not significant, Holm p = 1)Nemotron-Nano-9B-v2, Thinking vs plain: +12.1 (significant, Holm p = 2.68e-08)Nemotron-Nano-9B-v2, Thinking vs plain: +12.1 (significant, Holm p = 2.68e-08)OLMo-3-7BOLMo-3-7B, Check + retry vs plain: +0.1 (not significant, Holm p = 1)Confident-wrong change (per 1,000)-60-40-200+20Qwen3.5-9B, Check + retry vs plain: +0.0 (not significant, Holm p = 1)Qwen3.5-9B, Thinking vs plain: -20.0 (significant, Holm p = 0.0107)Qwen3.5-9B, Thinking vs plain: -20.0 (significant, Holm p = 0.0107)gpt-oss-20b, Check + retry vs plain: +6.0 (not significant, Holm p = 0.156)gpt-oss-20b, Thinking vs plain: -56.0 (significant, Holm p = 1.32e-07)gpt-oss-20b, Thinking vs plain: -56.0 (significant, Holm p = 1.32e-07)Granite-4.2-8B, Check + retry vs plain: +8.0 (not significant, Holm p = 0.0579)Granite-4.2-8B, Thinking vs plain: -26.0 (significant, Holm p = 0.0422)Granite-4.2-8B, Thinking vs plain: -26.0 (significant, Holm p = 0.0422)GLM-4.6V-Flash, Check + retry vs plain: +1.0 (not significant, Holm p = 1)GLM-4.6V-Flash, Thinking vs plain: -49.0 (significant, Holm p = 2.62e-08)GLM-4.6V-Flash, Thinking vs plain: -49.0 (significant, Holm p = 2.62e-08)Ministral-3-8B, Check + retry vs plain: +9.0 (significant, Holm p = 0.0422)Ministral-3-8B, Check + retry vs plain: +9.0 (significant, Holm p = 0.0422)Gemma-3-12B, Check + retry vs plain: +17.0 (significant, Holm p = 0.000244)Gemma-3-12B, Check + retry vs plain: +17.0 (significant, Holm p = 0.000244)Llama-3.1-8B, Check + retry vs plain: +22.0 (significant, Holm p = 8.11e-06)Llama-3.1-8B, Check + retry vs plain: +22.0 (significant, Holm p = 8.11e-06)Phi-4, Check + retry vs plain: +16.0 (significant, Holm p = 0.000458)Phi-4, Check + retry vs plain: +16.0 (significant, Holm p = 0.000458)Nemotron-Nano-9B-v2, Check + retry vs plain: +0.0 (not significant, Holm p = 1)Nemotron-Nano-9B-v2, Thinking vs plain: -33.0 (not significant, Holm p = 0.0579)OLMo-3-7B, Check + retry vs plain: +0.0 (not significant, Holm p = 1)Check + retry vs plainThinking vs plainhollow = not significant (Holm)
Figure 11. Change from the plain setup, per model. Left: accuracy (points). Right: confident-wrong answers per 1,000 (negative is better). Filled: significant after Holm correction across all within-model comparisons.

6.1 Check + retry

When an answer fails a check, the model is told which one ("the quoted line does not appear on page 54") and answers once more; it is never told the answer. This raises accuracy by 0.1 to 3.9 points, significantly for 8 of the ten models, at little cost: only answers that fail a check are asked again (5–54% of answers, depending on the model).

But retrying never reduces confident-wrong answers, and for 4 models (Ministral-3-8B, Phi-4, Gemma-3-12B, Llama-3.1-8B) it significantly increases them. The mechanism is visible in the answers: told that its quote failed, a model often keeps its wrong number and finds a line that contains it, which now passes. For Phi-4, 16 of 177 retried answers moved from "caught" to "confident-wrong" in this way. A retry teaches the model to satisfy the checker, not to be right. Nemotron-Nano-9B-v2 shows the opposite failure: asked to retry, it answered "not found" almost every time.

6.2 Thinking

Five of the ten models have a reasoning mode (as does the supplementary Qwen3-8B). Thinking improved accuracy for 4 of them, by up to 11.4 points (GLM-4.6V-Flash), and reduced confident-wrong answers for all 5: Qwen3.5-9B 36→16, Granite-4.2-8B 64→38, Nemotron-Nano-9B-v2 105→72, gpt-oss-20b 112→56, GLM-4.6V-Flash 110→61 answers per 1,000 (4 of these reductions are significant). The lowest confident-wrong rate in the study is Qwen3.5-9B with thinking: 16 in 1,000.

The exception is Qwen3.5-9B, the strongest plain model, whose accuracy fell from 82.7% to 74.6% with thinking. The cause is the token budget, not the reasoning: it reasoned at length (mean 3,574 tokens) and hit the pre-registered 8,192-token limit on 180 questions, leaving 88 with no parseable answer. On the questions it finished, its accuracy was 85.1%.

Thinking: accuracy against the tokens it costsFor each model with a reasoning mode, the plain and thinking setups joined by a line: horizontal distance is the extra generation cost, vertical distance the accuracy gained or lost.501003001,0003,00010,00040%50%60%70%80%90%Generated tokens per answer (mean, log scale)Qwen3.5-9B, plain: 53 tokens, 82.7%Qwen3.5-9B, plain: 53 tokens, 82.7%Qwen3.5-9B, thinking: 3574 tokens, 74.6%Qwen3.5-9B, thinking: 3574 tokens, 74.6%Qwen3.5-9BGranite-4.2-8B, plain: 49 tokens, 73.3%Granite-4.2-8B, plain: 49 tokens, 73.3%Granite-4.2-8B, thinking: 2538 tokens, 81.3%Granite-4.2-8B, thinking: 2538 tokens, 81.3%Granite-4.2-8BNemotron-Nano-9B-v2, plain: 51 tokens, 42.3%Nemotron-Nano-9B-v2, plain: 51 tokens, 42.3%Nemotron-Nano-9B-v2, thinking: 606 tokens, 54.4%Nemotron-Nano-9B-v2, thinking: 606 tokens, 54.4%Nemotron-Nano-9B-v2gpt-oss-20b, plain: 109 tokens, 74.4%gpt-oss-20b, plain: 109 tokens, 74.4%gpt-oss-20b, thinking: 1904 tokens, 80.7%gpt-oss-20b, thinking: 1904 tokens, 80.7%gpt-oss-20bGLM-4.6V-Flash, plain: 50 tokens, 70.9%GLM-4.6V-Flash, plain: 50 tokens, 70.9%GLM-4.6V-Flash, thinking: 385 tokens, 82.3%GLM-4.6V-Flash, thinking: 385 tokens, 82.3%GLM-4.6V-FlashQwen3-8B, plain: 59 tokens, 66.1%Qwen3-8B, plain: 59 tokens, 66.1%Qwen3-8B, thinking: 969 tokens, 74.1%Qwen3-8B, thinking: 969 tokens, 74.1%Qwen3-8B *PlainThinking
Figure 12. The cost of thinking: mean generated tokens per answer (log scale) against accuracy. * supplementary baseline.

Thinking is expensive. It multiplies generated tokens by 67× (Qwen3.5-9B), 52× (Granite-4.2-8B), 12× (Nemotron-Nano-9B-v2), 18× (gpt-oss-20b), 8× (GLM-4.6V-Flash). On one RTX 4090 with 16 concurrent requests, a full 1,000-question run took 14 minutes for GLM-4.6V-Flash with thinking and 182 for Granite-4.2-8B, against 3–7 minutes in the plain setup.

7 · Discussion

Checkable evidence is necessary, not sufficient. Requiring a verbatim quote turned most errors into visible, rejectable ones: the checker is cheap, needs no model and no gold answer, and could run in any system that uses these models. What it cannot do is check that the number is the right figure on the line, or that its units are right. The residue is small for the best configurations (1.6% of answers at best) and substantial for most (up to 16.7%).

The residue is structured. 87% of confident-wrong answers are the right line read wrongly: the units header misapplied, or the neighbouring column taken. Both are checkable in principle. A stronger checker could require the model to quote the column header and the units statement as well as the line, and verify that the chosen figure sits under the quoted header; a units check could compare the stated scale with the table's own heading. These are engineering steps, not research problems, and they are the natural next version of the benchmark.

Retrying is not a free win. Feeding a model the name of the failed check improves accuracy a little, but it also turns some caught errors into uncaught ones. A system that retries should treat a passed retry with more suspicion than a passed first answer, or re-verify it more strictly.

Model choice matters more than setup. The spread between the best and worst model in the plain setup is 66 points; the largest gain from any setup is about 11. And the strongest model in the plain setup, Qwen3.5-9B, reaches 84.5% with no reasoning at all.

8 · Limitations

  • One prompt, temperature 0, one run. Results are for a single fixed prompt shared by all models; a prompt tuned per model could change rankings. Each configuration was run once.
  • US large-cap filings, text only. 45 companies, recent 10-K and 10-Q filings. No small caps, foreign filers, scanned documents, charts or images.
  • Three pages per question. The model is shown the right page plus two others; finding the page in a whole filing is a harder, separate task.
  • Units stated off-page. After the results we found 30 answerable questions (3.4%) whose page shows no units statement, because the filer states it once on an earlier page. The frozen dataset was not changed. Excluding them moves no model's accuracy by more than 2.3 points. The plain and check-and-retry rankings do not change; with thinking, Granite-4.2-8B moves ahead of GLM-4.6V-Flash (Appendix A).
  • Quality control was AI-assisted. The review of the 100-question samples was performed by an AI assistant under the author's direction. The author did not independently verify the full sample.
  • Error categories were not reviewed by hand. The protocol planned a hand review of 20 answers per model to confirm the automatic error categories; it was not carried out (recorded as a deviation). Outcomes themselves are exact, by construction; the categories are rule-based.
  • Thinking budget. The 8,192-token reasoning limit was fixed in advance; it truncated 180 of Qwen3.5-9B's and 97 of gpt-oss-20b's answers. A larger budget would likely raise their thinking-mode results.
  • Contamination. Models may have seen older filings in training. 89 of the 90 filings were filed in 2026, and eight of the ten models were released before 2026. A memorised answer must still come with a verbatim quote from the pages shown.
  • Precision. Phi-4 and Gemma-3-12B were run with FP8 weights to fit in 24 GB, and gpt-oss-20b in its native MXFP4; results at full precision may differ slightly.

9 · Reproducibility

Everything needed to check or repeat this study is public. The code, the protocol (with its deviations log) and each run's summary are on GitHub; the questions, page texts, every model reply including its reasoning, and the server logs are on Hugging Face. Each run records the model revision, the exact vLLM command, the prompt hash and the dataset fingerprint.

git clone https://github.com/pramana-research/filing-evidence.git && cd filing-evidence
uv sync --all-extras
uv run python hf_data.py pull                       # data, verified against the frozen fingerprint
uv run python runner.py qwen3.5-9b C1 --regrade     # re-grade stored replies (no GPU)
bash run_all.sh qwen3.5-9b                          # rerun a model (one 24 GB GPU)

Re-grading every stored reply reproduces every number on this page. These pages are generated from the stored results by report/build.py in the same repository.

Results per model

Each model has its own page with its scorecard, its profile by kind of content, what retry and thinking changed, and real examples of its correct and wrong answers.

References

  1. U.S. Securities and Exchange Commission. EDGAR full-text and submissions APIs. sec.gov/edgar.
  2. XBRL International. Inline XBRL Specification 1.1. xbrl.org.
  3. E. B. Wilson (1927). Probable inference, the law of succession, and statistical inference. Journal of the American Statistical Association 22(158), 209–212.
  4. Q. McNemar (1947). Note on the sampling error of the difference between correlated proportions or percentages. Psychometrika 12(2), 153–157.
  5. S. Holm (1979). A simple sequentially rejective multiple test procedure. Scandinavian Journal of Statistics 6(2), 65–70.
  6. W. Kwon et al. (2023). Efficient memory management for large language model serving with PagedAttention. SOSP '23. (vLLM)
  7. Model cards of the eleven models evaluated, on Hugging Face, at the pinned revisions listed on each model page.

Appendix

A · Sensitivity: questions without an on-page units statement

ModelC1 all 875C1 without 30C2 all 875C2 without 30C3 all 875C3 without 30
Qwen3.5-9B82.7%82.7%84.5%84.5%74.6%76.1%
gpt-oss-20b74.4%76.0%77.4%79.1%80.7%82.4%
Granite-4.2-8B73.3%74.4%76.2%77.3%81.3%83.6%
GLM-4.6V-Flash70.9%72.3%73.0%74.6%82.3%83.0%
Ministral-3-8B66.7%68.8%69.6%71.7%n/an/a
Gemma-3-12B61.4%63.4%64.3%66.5%n/an/a
Llama-3.1-8B58.9%60.4%62.7%64.4%n/an/a
Phi-457.3%58.9%60.8%62.5%n/an/a
Nemotron-Nano-9B-v242.3%43.8%42.4%43.9%54.4%56.0%
OLMo-3-7B17.1%17.4%17.3%17.5%n/an/a

B · Within-model comparisons

ModelComparisonAccuracy: only A / only BHolm pConf.-wrong: only A / only BHolm p
Qwen3.5-9BC1 vs C20 / 150.0004270 / 01
Qwen3.5-9BC1 vs C3159 / 887.35e-0527 / 70.0107
Qwen3.5-9BC2 vs C3162 / 764.35e-0727 / 70.0107
Granite-4.2-8BC1 vs C20 / 264.77e-070 / 80.0579
Granite-4.2-8BC1 vs C391 / 1610.0001151 / 250.0422
Granite-4.2-8BC2 vs C396 / 1400.020156 / 220.00209
Ministral-3-8BC1 vs C20 / 257.75e-070 / 90.0422
OLMo-3-7BC1 vs C20 / 110 / 01
Nemotron-Nano-9B-v2C1 vs C20 / 110 / 01
Nemotron-Nano-9B-v2C1 vs C3100 / 2062.68e-0886 / 530.0579
Nemotron-Nano-9B-v2C2 vs C3101 / 2063.91e-0886 / 530.0579
gpt-oss-20bC1 vs C20 / 264.77e-070 / 60.156
gpt-oss-20bC1 vs C367 / 1220.00046276 / 201.32e-07
gpt-oss-20bC2 vs C374 / 1030.10579 / 172.09e-09
Phi-4C1 vs C20 / 311.96e-080 / 160.000458
Gemma-3-12BC1 vs C20 / 264.77e-070 / 170.000244
GLM-4.6V-FlashC1 vs C20 / 194.2e-050 / 11
GLM-4.6V-FlashC1 vs C349 / 1491.45e-1159 / 102.62e-08
GLM-4.6V-FlashC2 vs C352 / 1334.08e-0860 / 101.6e-08
Llama-3.1-8BC1 vs C20 / 342.56e-090 / 228.11e-06
Qwen3-8BC1 vs C20 / 110.004880 / 70.0938
Qwen3-8BC1 vs C366 / 1361.14e-0567 / 103.73e-10
Qwen3-8BC2 vs C370 / 1290.00027873 / 93.17e-12

"Only A": questions right (or, for confident-wrong, wrong-but-passing) in the first setup only. Blue p-values are significant at α = 0.05 after Holm correction within each family.

C · Confident-wrong rate

Confident-wrong rate per model and setup, with 95% Wilson intervalsConfident-wrong rate for each model in each of its setups; the line is the 95% interval.0%5%10%15%20%Qwen3.5-9BQwen3.5-9B, Plain: 3.6% (95% CI 2.6–4.9%), 36 of 1000Qwen3.5-9B, Plain: 3.6% (95% CI 2.6–4.9%), 36 of 1000Qwen3.5-9B, Check + retry: 3.6% (95% CI 2.6–4.9%), 36 of 1000Qwen3.5-9B, Check + retry: 3.6% (95% CI 2.6–4.9%), 36 of 1000Qwen3.5-9B, Thinking: 1.6% (95% CI 1.0–2.6%), 16 of 1000Qwen3.5-9B, Thinking: 1.6% (95% CI 1.0–2.6%), 16 of 1000gpt-oss-20bgpt-oss-20b, Plain: 11.2% (95% CI 9.4–13.3%), 112 of 1000gpt-oss-20b, Plain: 11.2% (95% CI 9.4–13.3%), 112 of 1000gpt-oss-20b, Check + retry: 11.8% (95% CI 9.9–13.9%), 118 of 1000gpt-oss-20b, Check + retry: 11.8% (95% CI 9.9–13.9%), 118 of 1000gpt-oss-20b, Thinking: 5.6% (95% CI 4.3–7.2%), 56 of 1000gpt-oss-20b, Thinking: 5.6% (95% CI 4.3–7.2%), 56 of 1000Granite-4.2-8BGranite-4.2-8B, Plain: 6.4% (95% CI 5.0–8.1%), 64 of 1000Granite-4.2-8B, Plain: 6.4% (95% CI 5.0–8.1%), 64 of 1000Granite-4.2-8B, Check + retry: 7.2% (95% CI 5.8–9.0%), 72 of 1000Granite-4.2-8B, Check + retry: 7.2% (95% CI 5.8–9.0%), 72 of 1000Granite-4.2-8B, Thinking: 3.8% (95% CI 2.8–5.2%), 38 of 1000Granite-4.2-8B, Thinking: 3.8% (95% CI 2.8–5.2%), 38 of 1000GLM-4.6V-FlashGLM-4.6V-Flash, Plain: 11.0% (95% CI 9.2–13.1%), 110 of 1000GLM-4.6V-Flash, Plain: 11.0% (95% CI 9.2–13.1%), 110 of 1000GLM-4.6V-Flash, Check + retry: 11.1% (95% CI 9.3–13.2%), 111 of 1000GLM-4.6V-Flash, Check + retry: 11.1% (95% CI 9.3–13.2%), 111 of 1000GLM-4.6V-Flash, Thinking: 6.1% (95% CI 4.8–7.8%), 61 of 1000GLM-4.6V-Flash, Thinking: 6.1% (95% CI 4.8–7.8%), 61 of 1000Ministral-3-8BMinistral-3-8B, Plain: 7.7% (95% CI 6.2–9.5%), 77 of 1000Ministral-3-8B, Plain: 7.7% (95% CI 6.2–9.5%), 77 of 1000Ministral-3-8B, Check + retry: 8.6% (95% CI 7.0–10.5%), 86 of 1000Ministral-3-8B, Check + retry: 8.6% (95% CI 7.0–10.5%), 86 of 1000Gemma-3-12BGemma-3-12B, Plain: 11.7% (95% CI 9.9–13.8%), 117 of 1000Gemma-3-12B, Plain: 11.7% (95% CI 9.9–13.8%), 117 of 1000Gemma-3-12B, Check + retry: 13.4% (95% CI 11.4–15.7%), 134 of 1000Gemma-3-12B, Check + retry: 13.4% (95% CI 11.4–15.7%), 134 of 1000Llama-3.1-8BLlama-3.1-8B, Plain: 10.2% (95% CI 8.5–12.2%), 102 of 1000Llama-3.1-8B, Plain: 10.2% (95% CI 8.5–12.2%), 102 of 1000Llama-3.1-8B, Check + retry: 12.4% (95% CI 10.5–14.6%), 124 of 1000Llama-3.1-8B, Check + retry: 12.4% (95% CI 10.5–14.6%), 124 of 1000Phi-4Phi-4, Plain: 15.1% (95% CI 13.0–17.5%), 151 of 1000Phi-4, Plain: 15.1% (95% CI 13.0–17.5%), 151 of 1000Phi-4, Check + retry: 16.7% (95% CI 14.5–19.1%), 167 of 1000Phi-4, Check + retry: 16.7% (95% CI 14.5–19.1%), 167 of 1000Nemotron-Nano-9B-v2Nemotron-Nano-9B-v2, Plain: 10.5% (95% CI 8.7–12.6%), 105 of 1000Nemotron-Nano-9B-v2, Plain: 10.5% (95% CI 8.7–12.6%), 105 of 1000Nemotron-Nano-9B-v2, Check + retry: 10.5% (95% CI 8.7–12.6%), 105 of 1000Nemotron-Nano-9B-v2, Check + retry: 10.5% (95% CI 8.7–12.6%), 105 of 1000Nemotron-Nano-9B-v2, Thinking: 7.2% (95% CI 5.8–9.0%), 72 of 1000Nemotron-Nano-9B-v2, Thinking: 7.2% (95% CI 5.8–9.0%), 72 of 1000OLMo-3-7BOLMo-3-7B, Plain: 7.0% (95% CI 5.6–8.8%), 70 of 1000OLMo-3-7B, Plain: 7.0% (95% CI 5.6–8.8%), 70 of 1000OLMo-3-7B, Check + retry: 7.0% (95% CI 5.6–8.8%), 70 of 1000OLMo-3-7B, Check + retry: 7.0% (95% CI 5.6–8.8%), 70 of 1000PlainCheck + retryThinking
Figure 13. Confident-wrong rate with 95% Wilson intervals, per model and setup.

D · Deviations from the protocol

All changes made after the protocol was registered are logged with their date and reason in PROTOCOL.md §12. The ones that affect how results are read: the served context is 16,384 tokens (8,192 would have truncated thinking); C2 reuses C1's first answer; Qwen3-8B is a supplementary baseline; gpt-oss-20b's plain setup uses its lowest reasoning effort; a secondary accuracy-ignoring-scale metric was added; the error taxonomy counts a misplaced decimal point as a scale error; and the planned hand review of error categories was not carried out. All except the last were made before any main result.

Disclaimer

This is an independent community research report, written in a personal capacity; it does not represent the views of any employer or other organisation. It is not affiliated with, sponsored or endorsed by any company or model developer named here; all names and trademarks belong to their owners. Results describe specific model versions under one fixed setup and are not a general judgement of any model. The data, results and code are provided as is, without warranty, and may contain errors; check any figure against the original filing. Nothing here is financial, investment or legal advice.

How to cite

@misc{pramana2026filingevidence, title = {Show Your Work: Can Small Open Models Read SEC Filings with Evidence a Machine Can Check?}, author = {Nandula, Krishna}, organization = {Pramana Research}, year = {2026}, month = {nov}, eprint = {2611.24990}, archivePrefix = {arXiv}, primaryClass = {cs.SE}, doi = {10.48550/arXiv.2611.24990}, url = {https://arxiv.org/abs/2611.24990}, note = {Community research report, not peer-reviewed. Filing-Evidence benchmark, report version 1.1} }

This is a community research report; it has not been peer-reviewed. Text, data and figures are licensed under CC BY 4.0 and the code under the Apache License 2.0. Model outputs remain subject to each model's licence. Nothing here is investment advice.